W-Series Servo Drives (R88D-Wt@ With Fny-Ns115) - Omron CJ1W-NC271 - 12-2009 Operation Manual

Position control units
Table of Contents

Advertisement

Servo Parameter Area
4-5-3

W-series Servo Drives (R88D-WT@ with FNY-NS115)

Note
132
The Servo Parameters listed here can be used when the Position Control Unit
is used with an OMRON W-series Servo Drive (R88D-WT@) with a MECHA-
TROLINK-II I/F Unit (FNY-NS115).
For further details on each of the parameters, refer to the user's manuals for
W-series Servo Drives and MECHATROLINK-II I/F Unit (FNY-NS115).
The default settings for parameters Pn000 to Pn601 in the parameter tables
for the R88D-WT@ W-series Servo Drive used with the FNY-NS115 are auto-
matically set to the default parameter settings for when the FNY-NS115
MECHATROLINK-II I/F Unit is mounted to a W-series Servo Drive. Parame-
ters from Pn800 onwards are enabled when the FNY-NS115 is mounted. The
parameter names and default settings for these parameters follow those spec-
ified by the FNY-NS115.
The timing for Servo Parameters to be enabled are classified into the following
two types.
Online (online parameter): Changed settings are enabled immediately after
Offline (offline parameters): Changed settings are enabled when the Servo
The Details column indicates whether the following conditions apply to the
corresponding parameter.
• Online parameters that can be changed when the axis is stopped (Busy
Flag = 0) only.
• Parameters that are automatically set when a FNY-NS115 MECHA-
TROLINK-II I/F Unit is installed and Parameters that are used with fixed
set values are indicated in the Details column as "fixed" with the set value.
• Parameters with standard set values when using MECHATROLINK are
indicated in the Details column as "standard" with the set value. The stan-
dard settings are basic settings required when using the Position Control
Unit. This manual describes operations assuming standard settings are
being used.
For details on fixed and standard settings, refer to 6-4 Standard Settings for
Servo Drives Using MECHATROLINK.
Make sure that the equipment will not be adversely affected before changing
the Servo Parameters (WRITE SERVO PARAMETER, SAVE SERVO
PARAMETER). Refer to the Servo Drive's user's manual and always check
the effect of changing the settings before changing the Servo Parameters.
Servo Parameters have been written.
Drive power is cycled or DEVICE SETUP is exe-
cuted.
Section 4-5