Standard Settings for Servo Drives Using MECHATROLINK

6-4
Standard Settings for Servo Drives Using MECHATROLINK
6-4-1
G5-series Servo Drive Settings (R88D-KN@-ML2 with Built-in
MECHATROLINK-II Communications)
Compulsory Parameter
Settings
Standard Settings for I/O Signals Using MECHATROLINK
Note
When an R88D-KN@-ML2 G5-series Servo Drive (with built-in MECHA-
TROLINK-II communications) is used, the default settings for the Servo Drive
are the standard settings when the MECHATROLINK communications is
used.
The following Servo Parameter must be set to enable PCU control. Do not
change this setting.
Pn800 Communication Control
Parameter
Parameter
No.
name
Pn800
Communica-
tions control
All MECHATROLINK communications errors and warnings are used when the
PCU is controlling communications. Set the parameter so that they are all
detected. Leave Pn800 set to the default setting.
When an R88D-KN@-ML2 G5-series Servo Drive (with built-in MECHA-
TROLINK-II communications) is used, the default settings for the Servo Drive
are the standard settings for the I/O signal allocations when the MECHA-
TROLINK communications is used.
Standard I/O Signal Allocation
General-purpose input
POT
NOT
DEC
EXIT1
EXIT2
EXT3
STOP
The PCU uses the forward drive prohibited input, reverse drive prohibited
input, and origin return deceleration limit switch allocated in the Servo Drive's
external inputs as the forward rotation limit input signal, reverse rotation limit
input signal, and origin proximity input signal, respectively. The signal widths
of these input signals must be longer than the MECHATROLINK communica-
tions cycle. If the input signal width is shorter than the communications cycle,
the PCU will not be able to detect the input signal, and operation will not be
performed normally.
Unit
Fixed
setting
---
0
0: MECHATROLINK-II
communications
errors and warnings
are all detected.
R88D-KN@-ML2
CN1
13
1
7
2
8
25
9
26
12
3
11
4
10
5
Section 6-4
Details
Default
setting
0
BKIR
BKIRCOM
READY
READYCOM
ALM
ALMCOM
263