Axis Parameter Area
PCU's
address
15 to 14
13
d
Origin input signal selection
d+1
0 (fixed) Origin
search
preset
d+2
0 (fixed)
Note
4-4-2

Axis Parameter Details

Data Details
102
Contents
12
11 to 08
07 to 04
Interrupt input sig-
nal selection
Origin
Origin
Origin
search
detection
search
direction
method
operation
0 (fixed)
0 (fixed)
The reversal mode 3 setting for the origin search operation, the origin detec-
tion method, and the origin search preset can be used only with Position Con-
trol Units with unit version 2.0 or later. They cannot be used with Position
Control Units with unit version 1.3 or earlier.
For details on transferring data, refer to SECTION 5 Transferring and Saving
Data.
The data set in the Axis Parameter Area is as follows:
d = 1860 hex + (Axis No. −1) × 14 hex
Unit address
d
Input signal selection
Data con-
15
figuration
d
Origin input signal
selection
Origin Input Signal Selection
Use this parameter to select the origin input signal to be used with origin
search.
00: Phase Z
01: External latch signal 1 input
02: External latch signal 2 input
03: External latch signal 3 input
03 to 00
Select the origin input signal and interrupt input
signal.
00: Phase Z (default setting)
01: External latch signal 1 input
02: External latch signal 2 input
03: External latch signal 3 input
0 (fixed)
Set the origin search operation.
Origin search direction
0: Reversal mode 1 (default setting)
1: Reverse mode 2
2: Single-direction mode
3: Reversal mode 3 (See note.)
Origin detection method (See note.)
0: With origin proximity input signal reversal
(default setting)
1: Without origin proximity input signal reversal
2: Not use origin proximity input signal
Origin search direction
0: Forward (default setting)
1: Reverse
Origin search preset (See note.)
0: Not Set (default setting)
1: Set
Encoder
0: Incremental encoder (default setting)
type
1: Absolute encoder
Name
08 07
00
Data setting range
Origin input signal
Interrupt input signal
selection
selection: 00 to 03
Interrupt input signal
selection: 00 to 03
Section 4-4
Setting
Enable timing
After comple-
tion of data writ-
ing
Default
0000