Parameter Copy Or Verify Errors - Omron SYSDRIVE 3G3MV SERIES User Manual

Sysdrive 3g3mv series multi-function compact inverter
Hide thumbs Also See for SYSDRIVE 3G3MV SERIES:
Table of Contents

Advertisement

Preparing for Operation and Monitoring
Key sequence
Indicator
In approximately
1 s.

3-2-4 Parameter Copy or Verify Errors

• The following description provides information on errors that may result while the parameter set val-
ues are read, copied, or verified, and the remedies to be taken. The display flashes while displaying
these errors.
Display
Name
pre
Protection error
rde
Read error
cse
Checksum error
nde
No data error
cpe
Copy error
cye
Copy voltage error
uae
Capacity error
ife
Communications error A communications error resulted
3-18
Display
example
Press the Enter Key so that the set value will be
entered and the data display will be lit.
The parameter number will be displayed again in
approximately 1 s.
Probable cause
An attempt was made to read the
parameter set values while n177
for parameter read-prohibit
selection was set to 0.
The parameter set values were
not read correctly or a main-circuit
low voltage was detected while
the parameter set values were
read.
A checksum error resulted in the
parameter set values in the
EEPROM of the Digital Operator.
There are no parameter set values
stored in the EEPROM of the
Digital Operator.
An attempt was made to copy or
verify the parameter set values
while the Inverters are different to
each other in voltage or control
mode.
Main-circuit low voltage is
detected while the Inverter was
copying the parameter set values.
An attempt was made to verify the
parameter set values while the
Inverters were different to each
other in capacity.
between the Inverter and Digital
Operator.
Chapter 3
Explanation
Remedy
Set n177 to 1 and retry after
rechecking the necessity of
reading the parameter set values.
Retry after checking that the
voltage of the main circuit is
normal.
Read the parameter set values
again and store them in the
EEPROM.
Read the parameter set values
and store them in the EEPROM.
Check that the Inverters are the
same in voltage and control mode.
If either of them is different, no
parameter set values can be
either copied or verified.
If the Inverters are different only in
control mode, retry after changing
the mode of the Inverter to which
the parameter set values are to be
written.
Retry after checking that the
voltage of the main circuit is
normal.
To continue verifying the
parameter set values, press the
Enter Key.
To cancel the operation, press the
STOP/RESET Key.
Retry after checking the
connection between the Inverter
and Digital Operator.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents