Overtorque/Undertorque Detection Function - Omron SYSDRIVE 3G3MV SERIES User Manual

Sysdrive 3g3mv series multi-function compact inverter
Hide thumbs Also See for SYSDRIVE 3G3MV SERIES:
Table of Contents

Advertisement

Advanced Operation
6-7

Overtorque/Undertorque Detection Function

When an excessive load is applied to the equipment, the Inverter detects the overtorque
condition through an increase in the output current. The Inverter detects the undertor-
que condition through a decrease in the output current (or output torque) generated
when a small load is applied to the equipment.
n096
Overtorque Detection Function
Selection 1
Setting
0 to 4
range
Set Values
Value
0
Inverter does not monitor overtorque.
1
Inverter monitors overtorque only when speed is matched. It continues operation (issues
warning) even after overtorque is detected.
2
Inverter monitors overtorque only when speed is matched. It discontinues operation
(through protective function) when overtorque is detected.
3
Inverter always monitors overtorque during operation. It continues operation (issues
warning) even after overtorque is detected.
4
Inverter always monitors overtorque during operation. It discontinues operation (through
protective function) when overtorque is detected.
• Set n097 (overtorque detection function selection 2), n098 (overtorque detection level) and n099
(overtorque detection time) to enable the overtorque detection function. The Inverter will detect over-
torque when the current is the same as or higher than the detection level is output for the preset detec-
tion time.
• Set a multi-function output (n057 to n059) to either of the following so that external overtorque detec-
tion output will be ON.
Set Value: 6 for overtorque detection (NO)
Set Value: 7 for overtorque detection (NC)
Overtorque Detection
Output current
(or output torque)
Overtorque
detection (NO)
Note Overtorque detection will be canceled if the output current decreases from the detection level by
approximately 5% of the Inverter rated current.
n099
Overtorque detection time
Register
0160 Hex
Unit of
1
setting
Description
See note.
Chapter 6
Changes during
No
operation
Default setting
0
n098 (Overtorque
detection level)
Time
Time
6-31

Hide quick links: