PGM.FI SYSTEM
2.
CMP
Sensor Line
Open
Circuit lnspection
Turn
the
ignition switch OFF'
oiiconn"6t the ECM 33P
(Black)
and 33P
(Gray)
connectors
(Page
4-42)
CtrecX
tor
continuity between
the
CMP sensor
2P
(Black) connector
[1],
and
-
EC.M
33P
(Black)
connector
l2), and 33P
(Gray) connector
t3l
terminals
at
the
wire
side.
TOOL:
Gr/R
(B16)
Test probe
(2
Pack)
O7ZAJ.RDJA11O
CONNEGTION: White
-
White/yellow
(A31)
GraY/red
-
GraY/red (816)
ls
there
continuitY?
YES
-
GOTO
STEP
3.
NO - '
Open circuit
in
the White
or
White/
Yellow
wire
.
bPen
circuit
in
the GraY/red
wire
CMP
Sensor Line Short Circuit lnspection
Check for continuity
between
the wire harness
side
CMP sensor 2P (Biack) connector [1] and
ground'
CONNEGTION:
GraY/red
-
Ground
Is
there
continuitY?
YES
-
Short circuit
in
the
Gray/red
wire
NO -
Replace
the
ECM
with
a
known good
one
and
recheck.
DTC 19 (CKP SENSOR)
CKP
SENSOR
[=-w
tc
I
l.--l-Y
Probable cause
.
Open circuit
in the
White/yellow
wire
between
the
CKP sensor
and
ECM
Open or short circuii
in
the Yellow wire
between the
CMP sensor
and
ECM
Faulty CKP sensor
Faulty
ECM
ECM
4-31