Cabinet and equipment wiring and cabling 13-67

Service protection center protector block wiring

The service protection center VF protector blocks are connectorized for the VF
line feeds from the CDS shelves (see Figure 13-41 on page 13-65,
Figure 13-42 on page 13-66 and Figure 13-43 on page 13-68).
The equipment side connections from the CDS shelves are internally wired to
the equipment side of the protector plug position (see Figure 13-44 on page
13-69).
The last four pairs (22–25) in the VF cable from CDS VF connector 76–96 are
not used. Protector block positions 97-100 are unused in S800A applications.
The line or outside plant side of the VF protector block is connectorized with
the optional BIX or 710 type connectors or with 3M screw-down
cross-connect terminal blocks mounted on the SAI swing frame.
Figure 13-43 on page 13-68 shows the VF protector block connector layout.
Figure 13-44 on page 13-69 shows the VF protector block pin configuration
and layout.