Procedure; Installing The Cable Bonding Clamps - Nortel SONET AccessNode 800A Series Manual

Outside plant cabinet installation
Table of Contents

Advertisement

4-16 Installing the OSP cables

Procedure 4-4

Installing the cable bonding clamps

This procedure explains how to install the cable bonding clamp and ground the
600 pair VF, miscellaneous, T1, maintenance and fiber cables for installation
into the Series 800A cabinet.
Use Figure 4-3 on page 4-18 and Figure 4-4 on page 4-19 for all steps in this
procedure.
Precautions
The following safety precautions should be observed at all times during the
cable sheath bonding and grounding procedures:
Prerequisites
Ensure that Procedure 4-1 through Procedure 4-3 have been completed.
Tools required
Material required
AccessNode 323-3001-210 Issue 1.0
No equipment should be installed until the cabinet is firmly secured to its
mounting pad, as described in Chapter 2, "Installing the cabinet".
Do not open the front or rear doors unless the cabinet is firmly secured to
the mounting pad.
Observe all NEC and local codes for electrical wiring.
CAUTION 1
Electrical shock hazard
The procedures listed in this chart should be done by a
qualified electrician. The procedures outlined are
recommended guidelines; be sure to follow all local codes
for wiring procedures.
one 6-8-inch (15–20 cm) adjustable wrench
cable knife or cable sheath cutter
voltmeter
standard cable butting, stripping and fanning tools
cable insulating gel removal material; D-gel or equivalent de-greaser
electrical tape
—continued—

Advertisement

Table of Contents
loading

Table of Contents