Honeywell SmartLine Multivariable SMV800 Series User Manual page 79

Hart/de option
Hide thumbs Also See for SmartLine Multivariable SMV800 Series:
Table of Contents

Advertisement

Pages
Group
Manufacturing
Meter Body details
Meter Body
General
Device Info
Meter Body
Materials
Temperature
sensor
input/output
Electronic
selections
Protocols and
Interfaces
Revision 6.0
Parameter
Manufacturer
Model
MB Type
MB ID
Device ID
Model number
Fill fluid
Process Connection
Vent Head type
Vent/Drain location
MB Connection
Orientation
Process/Head
material
Diaphragm Material
Bolt/Nut Material
Vent Material
Gasket Material
Temp Sensor Input
Tempe Sensor
Type
Electronics Housing
Material
Connection Type
Lightning Protection
Ext Zero, Span
Config Buttons
Analog Output
Digital Output
Customer Interface
Indicator
Languages
SMV800 Series HART/DE Option User's Manual
Description
Manufacturer of the transmitter
Device model (ST 800, SMV800 etc) or Device
Type of SMV800 Transmitter
Measurement type. Type of measurement
application this device is intended to be used
with
The serial number of the Meter Body
HART unique ID of the SMV800 Transmitter
Model number of the SMV800 Pressure
Transmitter
Fill fluid used in the Meter Body
Size and type of the Meter Body process
piping connection ports
Identifies the installation of single or dual vent
connection ports for the Meter Body
Location details of the vent/drain ports in the
Meter Body
The rotation orientation of the Meter Body
process heads and piping connection ports
Material of construction for the Meter Body
process heads
Material of construction for the Meter Body
diaphragm
Material of construction for the nuts and bolts
used in Meter Body
Material of construction for the Meter Body
vent ports
Material of construction for the Meter Body
gaskets
Identifies the availability of single or dual
temperature sensor input
Identifies the availability of the type of sensor
input (RTD-only input or Universal)
Material of construction for the electronics
housing
Size/type of wiring conduit ports on the
housing
Identifies if lightning protection is installed
Identifies the selection of external calibration
buttons available
Identifies the availability of Analog Output
Identifies the device Digital Communications
Protocol (HART, DE, FF)
Identifies the type of Display available (None
or Advanced)
Identifies the selection of languages available
via the Display and communications hosts
Page 67