Table of Contents
Honeywell Process Solutions
3
Symbol Definitions
6
Table of Contents
9
1 Introduction
15
Purpose
15
Scope
15
Onewireless Network Overview
15
Security Considerations
15
Licensing and License Keys for Anti-Aliasing Filter
15
About the Transmitter
16
Figure 1-1 - Smartline Wireless Transmitter Functional Diagram
17
Physical Characteristics
18
Figure 1-2 - Smartline Wireless Transmitter Major Assemblies
18
Figure 1-3- Smartline Wireless Transmitter Electronics Housing Components
19
2 Preparation and Quick Start
20
Introduction
20
Set up the Network
20
Transmitter Quick Start
20
3 Installation
22
3.1 Installation Site Evaluation
22
Maximum Working Pressure
22
Environmental Conditions
22
Transmitter Weights and Dimensions
23
Weights
23
Table 3-1: Weights
23
Dimensions
24
Figure 3-1: DP/DHGP Pressure Transmitter Dimensions Unit MM/Inch
24
Figure 3-2: DP/DHGP Pressure Antenna Dimensions Unit MM/Inch
25
Figure 3-3: GP/AP Pressure Transmitter Dimensions Unit MM/Inch
26
Figure 3-4: GP/AP Pressure Antenna Dimensions Unit MM/Inch
27
Installation Drawing Number Tables
28
Table 3-2: Drawing Numbers for Pressure Transmitters
28
Conduit / Cable Entries
29
Summary
29
Table 3-3: Conduit Entry Plugs and Cable Glands for Your Transmitter
29
Mounting Summary
30
Figure 3-5: Typical Bracket Mounted and Flange Mounted Installations
30
Figure 3-6: Angle Mounting Bracket Secured to a Horizontal or Vertical Pipe
31
Figure 3-7: - Inline Model Mounted to an Optional Bracket
32
Figure 3-8: Rotating the Electronic Housing
32
Figure 3-9: Using a Spirit Balance to Level a Transmitter
34
Figure 3-10: Tank-Flange Mounted Transmitter
35
Table 3-4: Flange Mounting Guidelines
36
Figure 3-11: Representative Remote Diaphragm Seal Transmitter Installation
36
Piping the Smartline Wireless Transmitter
37
Table 3-5: Remote Diaphragm Mounting Details
37
Figure 3-12: Typical 3-Valve Manifold with Blow-Down Piping
38
Table 3-6: Suggested Connection Locations
39
Figure 3-13: Flange Adapter Removal and Replacement
40
Rotate Transmitter Housing
41
3.10 Rotate Display
41
Tools Required
41
Procedure
41
Figure 3-14: Rotating Transmitter Housing
41
Display Adjustment
42
Figure 3-15: Display Rotation
42
3.11 Antenna Adjustment and Mounting
43
Requirements
43
Integral Antenna
43
Figure 3-16: Elbow Antenna Adjustment
44
3.12 Remote Antenna
45
Outdoor Installation Warnings
45
Choosing a Mounting Location
46
Site Selection
46
Mounting the Antenna
47
Directional Mounting Procedure
48
Omnidirectional Mounting Procedure
49
Figure 3-17: Directional Antenna Mounting
49
Grounding the Antenna
50
Figure 3-18: Omnidirectional Antenna Mounting
50
4 Start up
52
Battery Power Option
52
Install/Replace Batteries
52
Figure 4-1: IS Battery Pack Installation
53
Figure 4-2: IS Battery Pack
53
Battery Pack Installation and Replacement Procedure
54
Battery Pack Test Terminals
54
Power Supply Option
55
Figure 4-3: 24V Power Supply Installation
55
24V Power Supply
56
Figure 4-4: 24V Power Supply Module
56
24V Power Supply Connection/Replacement Procedure
57
Grounding
58
24V DC Power Supply Option (DC) System Diagram
58
Figure 4-5: Power Supply 24V DC Option (DC) System Diagram
58
Display Sequence
59
Provisioning
59
Calibrating the Transmitter
60
Overview
60
Calibrate Zero
60
Table 4-1: Calibrate Zero
60
Procedure for Field Calibration of Honeywell Compound Characterized Smartline Wireless Transmitters
61
Table 4-2: Field Calibration
61
5 Function Blocks
64
Introduction
64
Block Description
64
Block Types
64
Block Diagram
64
Table 5-1: Blocks
64
Figure 5-1: Block Diagram
64
6 Operation
65
Overview
65
Display Modes
65
Transmitter Connection Status
66
Table 6-1: Transmitter Connection Status
66
Transmitter PV Display
68
Table 6-2: Transmitter PV Display
68
Table 6-3: Smartline Wireless DP Units
68
Table 6-4: Smartline Wireless Flow Units
70
PV Status
71
Table 6-5: PV Status
71
Table 6-6: Device Status
72
Provisioning Device Menus
74
Overview
74
Main Menu
74
Security and Node Deployment
74
Figure 6-1: Main Menu
74
Figure 6-2: Security and Node Deployment
75
De-Provisioning
76
Read Device Information
76
Figure 6-3: Read Device Information
76
Table 6-7: Read Device Information
77
Advanced Options
78
Figure 6-4: Advanced Options
78
Table 6-8: Advanced Options
79
7 Maintenance/Repair
80
Introduction
80
Preventive Maintenance
80
Inspecting and Cleaning Barrier Diaphragms
80
Tools Required
80
Procedure
81
Table 7-1: Inspecting and Cleaning Barrier Diaphragms
81
Figure 7-1: Assembly of DP Transmitter Process Heads
82
Figure 7-2: STW Standard Transmitter - Head Bolt Tightening Sequence
82
Torque Ratings
83
Table 7-2: Head Bolt Torque Values
83
Replacing Electronics Module
84
Tools Required
84
Procedure
84
Table 7-3: Electronics Module Replacement
84
Replacing Batteries
85
When to Replace
85
Replacing 24V External Power Module
85
Figure 7-3: Sensor Module Removal and Replacement
85
Replacing Antenna
86
Tools Required
86
Procedure
86
Antenna Replacement Procedure
87
Figure 7-4: Antenna Replacement
88
8 Parts
89
Transmitter Body
89
Table 8-1: Transmitter Body Parts
89
Figure 8-1: Angle and Flat Bracket Parts
90
Mounting Brackets
90
Table 8-2: Angle and Flat Bracket Parts (Refer to Figure 8-1)
91
Table 8-3: Transmitter Enclosure O-Ring Kit
91
Table 8-4: Meter Body Parts
91
Table 8-5: Models STDW810, 820, 825, 830 & 870
92
Figure 8-2: Models STDW810, 820, 825, 830, & 870
94
Table 8-6: Parts for STGW830, 840, 870 and STAW822, 840 Transmitter Body
95
Figure 8-3: STGW830, 840, 870, and STAW822, 840 Transmitter Body
97
Figure 8-4: Inline Gauge and Inline Atmospheric Display Bodies
98
Table 8-7: Inline Gauge and Inline Atmospheric Meter Body Parts
98
Table 8-8: Flange-Mounted Meter Body Parts
98
Figure 8-5: Extended Flange Design
99
Figure 8-6: Pseudo Flange Design
99
Figure 8-7: Flush Flange Design
100
Figure 8-8: Remote Seal Diaphragm
100
Appendix A - Modbus
101
Table 8-9: Smartline Wireless Pressure - Modbus Table
101
Table 8-10 Smartline Wireless - Modbus Table
104
Appendix B - Certifications and Approvals
108
Hazardous Location Certifications
112
Battery
115
24V DC Supply
115
B3. Conditions of Certification
116
FM Approval Specific Conditions of Use
116
CSA, Iecex and ATEX Conditions of Certification
116
Apparatus Marked with Multiple Types of Protection
116
B4. Radio Compliance Information
117
Radio Frequency (RF) Statement
117
European Union Restriction
117
Restriction
117
Japanese Restrictions
118
FCC Compliance Statements
118
IC Compliance Statements
118
Advertisement
Advertisement
Related Products
Honeywell SmartEye Transmitter
Honeywell SmartLine ST 800
Honeywell SMV 3000
Honeywell SMV800
Honeywell STGW84L
Honeywell STFW828/724
Honeywell SmartLine SLN 700S
Honeywell SmartLine SLN 700 Series
Honeywell STAW84L
Honeywell STGW74L
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL