Honeywell SmartLine Multivariable SMV800 Series User Manual page 121

Hart/de option
Hide thumbs Also See for SmartLine Multivariable SMV800 Series:
Table of Contents

Advertisement

MB Electronics
temperature
(ET) Tracking
MBT Tracking
Sensor supply
voltage
Revision 6.0
Maximum ET
Min ET Value
Total time above upper
limit
Total time below lower
limit
ET Dn TimeStamp
ET Up TimeStamp
Maximum Value
Minimum Value
Total time above upper
limit
Total time below lower
limit
MBT Up Limit
MBT Dn Limit
MBT Up TimeStamp
MBT Dn TimeStamp
Maximum voltage
Minimum voltage
Time since above
upper limit
Time since below
lower limit
SMV800 Series HART/DE Option User's Manual
Pressure Module Electronics Temperature
(ET) highest measured value
Pressure Module Electronics Temperature
(ET) lowest measured value
The total number of minutes that the
Pressure Module Electronics Temperature
(ET) has exceeded the upper stress limit
The total number of minutes that the
Pressure Module Electronics Temperature
(ET) has been below the lower stress limit
Displays time elapsed since the Pressure
Module Electronics Temperature was last
measured below the ET lower stress limit
Displays time elapsed since the Pressure
Module Electronics Temperature last
measured as exceeding the ET upper stress
limit
Meter Body Temperature (MBT) highest
measured value
Pressure Module Meter BodyTemperature
(MBT) lowest measured value
The total number of minutes that the Meter
Body Temperature (MBT) has exceeded the
upper stress limit
The total number of minutes that the Meter
Body Temperature (MBT) has been below
the lower stress limit
High Meter Body Temperature stress limit – if
the Meter Body Temperature exceeds this
limit, the MBT Up Count and MBT Up
Timestamp will be updated. Value is equal to
"Max MBT Limit" minus 10% of limits range.
Low Meter Body Temperature stress limit – if
the Meter Body Temperature drops below
this limit, the MBT Down Count and MBT
Down Timestamp will be updated. Value is
equal to "Min MBT Limit" plus 10% of limits
range.
Displays time elapsed since the Meter Body
Temperature last measured as exceeding
the MBT upper stress limit
Displays time elapsed since the Meter Body
Temperature was last measured below the
MBT lower stress limit
Displays the highest recorded value of the
Pressure Sensor Supply Voltage (AVDD)
Displays the lowest recorded value of the
Pressure Sensor Supply Voltage (AVDD)
Displays the time elapsed since the Pressure
Sensor Supply Voltage last exceeded the
Max supply voltage Value
Displays the time elapsed since the Pressure
Sensor Supply Voltage last dropped below
the Min supply voltage Value
Page 109