Ramp Replacement

This procedure provides instruction to replace the Ramp assembly.

Procedure

Review entire procedure before starting.
WARNING: Care must be taken when work is being performed in the area of the
stairarms. Pinch points exist between the stairarm and ramp and between the
stairarm and crankarm, when the rear covers are removed.
Removal
1. Switch the power ON..
2. Start a manual workout and raise the incline to maximum incline.
3. Switch the power OFF and
4. Remove these rear drive covers: the drive cover access panel, top, left, and right
drive covers (see
5. Remove the stairarm, see
6. Remove the ramp lower pivot mounting bolts (2x), pivot sleeves (2x), flat washers
(2x), wave washers (2x) and flat washes (2x) from the left and right lower pivot frame
mounting bracket.
1
Disconnect a device power cord plug or cable connector from the power receptacle or out-
let.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
1
unplug
the power cord.
"Covers and Panels Replacement" on
"Stairarm Assembly Replacement" on
6 Available Replacement Procedures
Ramp Replacement
page 75).