Power Entry Module Replacement

This procedure provides instruction to replace the Power Entry Module and how to verify
and replace the input fuses.

Procedure

Review entire procedure before starting. This procedure applies to both the left and right
stairarms.
Removal
1. Switch the power OFF and
2. Remove these rear drive covers: the drive cover access panel, top, left, and right
drive covers (see
3. Unplug the power cord from the Power Entry Module.
4. Disconnect the blue wire from terminal D, the brown wire from terminal A, and the
green wire from the chassis ground "GND" terminal on the back of the power entry
module.
5. Remove the two screws that fasten the power entry module to the bottom cover.
Remove the power entry module from the bottom cover.
1
Disconnect a device power cord plug or cable connector from the power receptacle or out-
let.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
1
unplug
the power cord from the wall power outlet.
"Covers and Panels Replacement" on
6 Available Replacement Procedures
Power Entry Module Replacement
page 75).