Operation Verification; R40 Operation Verification Test - Precor Precision 400 Series Service Manual

Hide thumbs Also See for Precision 400 Series:
Table of Contents

Advertisement

Operation Verification

The Operation Verification tests verify that the machine is operating correctly and can be
returned to service. Do these operation verification tests at the end of a maintenance pro-
cedure or whenever it is necessary to ensure that the machine is operating properly. There
are separate procedures for the R40 and R20 consoles

R40 Operation Verification Test

The Operation Verification Test applies to equipment configured with the R40 console. Com-
plete each test to verify the equipment operation.
Error Code Verification Test
Verify that there are no current active logged error codes:
1. Access the Error Log and record any current active logged error codes:
From the Home screen press Settings > Information > Error Log.
l
Take note of all the errors starting with C – 001. Also note the error odo-
meter information which can help determine the age and relevance of the
error.
2. Resolve any current active logged error code issues.
3. Press HOME to exit the Error Log.
4. Clear error codes and Reset the Error Log:
Access the Hardware Validation (51765761) service menu, see
l
ard Service Menus" on
Use the down arrow softkey to scroll down and select the Error Log
l
Reset softkey.
Select Test > Start. The screen will transition to the System Settings
l
menu. The test will run but there will no messages or indicators showing
that it has completed.
5. Verify that all active error codes have been cleared from the Error Log.
Cycle the power OFF/ON.
l
Wait for the power-up sequence to complete, then go to the Error Log
l
and verify that all active error codes starting with C – 001 have been
cleared (press Settings > Information > Error Log).
Press Home to exit.
l
Hardware Validation Tests Verification
Verify that each of following Hardware Validation tests are successfully completed.
1. Access the Hardware Validation service menu (51765761) and perform the fol-
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
page 36.
3 Operation Verification
R40 Operation Verification Test
"Stand-
Page 19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Precision efx400-14Precision efx400-18

Table of Contents