Procedure 7.13 - Replacing a Ramp Assembly

Procedure
1.
Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower
PCA.
2.
Rotate both stairarms to the rear of the unit.
3.
Remove the bolts that fasten the lift yoke into the ramp assembly. Slide the lift yoke out of
the ramp assembly and rotate the ramp assembly toward the rear of the unit.
4.
Remove four rear ramp mounting bolts (2 each side). See Diagram 7.8.
Diagram 7.8 - Rear Ramp Mounting
Mounting
Bolt
5.
Remove the ramp from the EFX.
6.
Set the ramp assembly at its mounting position. Hand start the four rear mounting bolts.
Slide the lift yoke into the ramp and replace and hand tighten the yoke mounting bolts.
Torque the rear mounting bolts to 120 inch pounds. Torque the yoke mounting bolts to 240
inch pounds.
7.
Rotate both stairarms forward onto the ramp assembly.
8.
Reconnect the red battery lead removed in step 1 and replace the rear cover.
C546i Self Powered Elliptical Fitness Crosstrainer
Ramp
Mounting
Bracket