Clearing The Error Log; Error Code Troubleshooting Guide - Precor Precision 400 Series Service Manual

Hide thumbs Also See for Precision 400 Series:
Table of Contents

Advertisement

Clearing the Error Log

The Error Log history is cleared by 1) running the Hardware Validation "Error Log Reset"
systems test and 2) cycling the input power.
1. Go to the Hardware Validation Systems Tests page (Service Access Code
51765761), see Accessing Service Software.
2. Use Up/Down arrow softkeys to select the Error Log Reset > Test.
3. Select Start to reset the Error Log.
4. Cycle the input power (OFF/ON).
5. Go to the Display Error Log page and verify that all error codes have been cleared,
select Settings > Information > Error Log).
6. Select Home to exit and return to the Home page.

Error Code Troubleshooting Guide

There is a set of standard error codes implemented across Precor exercise equipment.
Error codes are system generated error codes designed to detect and report fault con-
ditions. Each error code is associated with a particular system or component fault condition.
The maintenance software monitors error code event conditions, when a fault is detected,
the error code is stored in the Error Log along with the event mileage, hours, and motor cur-
rent.
Error Code Troubleshooting Guide:
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Error Code Troubleshooting
7 Troubleshooting
Error Log Display
Guide.