Procedure 7.18 - Replacing A Ramp Assembly - Precor EFX 5.33 Service Manual

Elliptical fitness crosstrainer
Hide thumbs Also See for EFX 5.33:
Table of Contents

Advertisement

Procedure 7.18 - Replacing a Ramp Assembly

Warning: Care must be taken when work is being performed in the area of the stairarms. Pinch
points exist between the stairarm and ramp and between the stairarm and crankarm,
when the rear covers are removed.
Procedure
1.
Set the on/off switch in the off position.
2.
Remove the front, top, left and right cover sections per Procedure 7.1.
3.
Remove three bolts, washers and single nut that fasten the stairarm connector to the
stairarm. See Diagram 7.25.
4.
Rotate both stairarms to the rear, so that they are resting on the floor to the rear of the EFX.
Diagram 7.20 - Lower Ramp Mounting
Ramp Bracket
5.
Remove the screw that fastens the ramp end cap to the ramp. Remove the ramp end cap.
6.
Remove the four bolts that fasten the ramp to the rear ramp bracket (See Diagram 7.20).
7.
Remove two bolts, four washers and two nuts that fasten the ramp to the front ramp support.
(See Diagram 7.28)
8.
Remove the ramp from the EFX.
5.33 Ellipitical Fitness Crosstrainer
Ramp
Mounting Bolt
Page 66