8. To remove an existing CPU module by using torque tool A:
a. Alternately rotate the left and right captive screws one turn counterclockwise
until the screws are free of the threaded inserts (see
Caution – Do not touch the board for the CPU module or its components. Touch
only the captive screws and plastic top cover of the module to avoid damaging
module components by electrostatic discharge (see
b. Use both hands to lift the CPU module out of the shroud.
c. Place the CPU module on an antistatic mat with the heat sink on the top facing
up. Proceed to Section 8.2.3, "Replacing an UltraSPARC III CPU Module" on
page 8-12.
9. To remove an existing CPU module by using torque tool B:
a. Remove the cover for the shroud (see
Squeeze the two tabs to release the shroud from the motherboard.
Chapter 8 Removing and Replacing the Motherboard and Associated Components
FIGURE 8-5
).
FIGURE 8-8
).
FIGURE 8-6
).
8-9