Northern Telecom NAC User Manual page 75

Network administration center
Hide thumbs Also See for NAC:
Table of Contents

Advertisement

Table 5-1
Fatal error messages
Error Message
Task
Explanation
Error Recovery Procedure
"fstat check failed on pipe from cclink"
ncc_sched
Either insufficient memory was installed in the system, irregular system activities occurred, or
a software error was detected.
The task should begin its recovery process and will start again without user intervention. If the
problem reoccurs then shut down the system and call your Northern Telecom service
representative.
"fstat check failed on pipe from cc_request"
ncc_sched
Either insufficient memory was installed in the system, irregular system activities occurred, or
a software error was detected.
The task should begin its recovery process and will start again without user intervention. If the
problem reoccurs then shut down the system and call your Northern Telecom service
representative.
"fstat failed [%d]"
LangServer
Either insufficient memory was installed in the system, irregular system activities occurred, or
a software error was detected.
The task should begin its recovery process and will start again without user intervention. If the
problem reoccurs then shut down the system and call your Northern Telecom service
representative.
"Gfield failure [%d] –– table: %s,field: %s"
display
A database error has occurred.
Reinstall the hardware and software if there were errors during the most recent
installation/upgrade of the NAC system. If there were no errors during the installation/upgrade,
or if the problem persists after reinstallation, call your Northern Telecom service representative.
"hangup signal received"
signal processor
Either insufficient memory was installed in the system, irregular system activities occurred, or
a software error was detected.
The task should begin its recovery process and will start again without user intervention. If the
problem reoccurs, then call your Northern Telecom service representative.
"header not found in input pipe"
MAPA Client
Installation failed or the site has an improper version of the release materials.
Check your release materials (that is, version number and system type). If they are correct, then
reinstall the NAC system. Otherwise, call your Northern Telecom service representative.
Network Administration Center System Administration and Maintenance Guide Product release 2
Module
Uncc_sched.c
Uncc_sched.c
lang.c
Uremote.c
Usignal.c
client.c
NAC error messages 5-25

Advertisement

Table of Contents
loading