A.2 
Safety data sheet for ceramic fiber
products
July 1, 1996
A.2.1 
Identification
Product name
Chemical family
Chemical name
Chemical formula
Manufacturer's name
and address
Health hazard
summary warning
Rosemount OCX8800A
Ceramic fiber heaters, molded insulation modules,
and ceramic fiber radiant heater panels
Vitreous aluminosilicate fibers with silicon dioxide
N/A
N/A
Watlow Columbia
2101 Pennsylvania Drive
Columbia, MO 65202
Phone: 573-814-1300, ext. 5170
Fax: 573-474-9402
Possible cancer hazard based on tests with
laboratory animals.
May be irritating to skin, eyes, and respiratory
tract.
May be harmful if inhaled.
Cristobalite (crystalline silica) formed at high
temperature (above 1800 °F [982 °C]) can cause
severe respiratory diseases.