7. Connect the ground lead to the ground stud. Secure the connection with
8. Install the cover on the electronics housing.
9. Restore power to the system. Allow the transmitter to reach normal
10. Bolt the transmitter to the stack and install insulation.
11. Turn on the test gases at the cylinders and open the instrument air supply
10.2.2 
Rosemount OCX8800 with remote electronics
Remove sensor housing
Procedure
1. Turn off power to the system.
2. Shut off the test gases at the cylinders and close the instrument air valve.
3. Disconnect the calibration gas, reference air, eductor air, and dilution air
Rosemount OCX8800A
two nuts. Attach a separate ground lead (G wire) from the ground stud to
the G terminal on the power input terminal block.
operating temperature before installing it in a hot process stack.
Refer to
Figure 10-2
and make sure all test gas lines and electrical
connections are complete.
valve.
lines from the sensor housing,
Maintenance and service
Figure
10-3.
December 2022
241