a. Position the mounting bracket against the server chassis (
the slide rail lock is at the front and the three keyed openings on the mounting
bracket are aligned with the three locating pins on the side of the chassis.
Attaching a Mounting Bracket to the Chassis
FIGURE 2-17
b. With the heads of the three locating pins protruding though the three keyed
openings in the mounting bracket, pull the mounting bracket toward the front
of the chassis until the bracket locks into place with an audible click.
c. Verify that all three locating pins are trapped in the keyed openings and that
the back locating pin has engaged the mounting bracket lock, as shown in the
right side of
FIGURE 2-17
3. Attach the second mounting bracket to the left side of the server chassis.
4. Determine which rack hole numbers to use when attaching the slide rails to the
rack posts.
The server is two rack units tall (2U). The slide rails will occupy the lower half of the
2U space.
.