27. Sterilization
Initial setting: 65°C 10min
Set timer to perform sterilization.
① Set operating day & time. (Weekly timer format)
② Sterilization temp (55~75°C
③ Operation time (Time to run sterilization when it reached setting temp
5min ~ 60min)
User shall set whether to use or not to use sterilization mode.
28. Force DHW Temp.
Set tank temperature to perform force DHW:
(When tank temperature drop below set point, will switch to tank only mode
and have higher priority for heat pump to heat up tank water by temporarily
stop room units operation.
Setting range is 25°C ~ 40°C
11.3.3.5
Service Setup
29. Pump maximum speed
Normally setting is not necessary.
Please adjust when need to reduce the pump sound etc.
Besides that, it has Air Purge function.
When *Pump flow setting is Max. Duty, this duty set is the fix pump duty run
during room side operation.
30. Dry concrete
Operate concrete curing operation.
Select Edit, set temp for every stage (1~99 1 is for 1 day).
Setting range is 25~55°C
When it is turned ON, dry concrete starts.
When it is 2 zone, it dries both zones.
31. Service contact
Able to set name & tel no. of contact
person when there is breakdown
etc. or client has trouble. (2 items)
If use back-up heater, it is 65°C)
Initial setting: 35°C
Initial setting: Depend on model
Service setup
Service contact:
Contact 1
Contact 2
Select
①     ③
Room Heating +
Tank Heating
35°C
Service setup
Flow rate
88:8 L/min
Select
45°C
40°C
35°C
30°C
1
2
3
4
12:00am,Mon
Contact-1: Bryan Adams
ABC/ abc
A B C D E F G H I J K L M N O P Q R
S T U V W X Y Z
j k l m n o p q r s t u v w x y z
Confirm
Select
93
Tank Heating only
12:00am,Mon
Max. Duty
Operation
Air Purge
0xCE
40°C
35°C
5
6
Stage
0-9/ Other
a b c d e f g h i
Enter