Panasonic WH-ADF0309J3E5CM Service Manual page 27

Table of Contents

Advertisement

Menu
Buffer tank connection
5.6
To connect tank to the system
and if selected YES, to set
T temperature.
• The optional PCB connectivity
must be selected YES to
enable the function.
• If the optional PCB
connectivity is not selected,
the function will not appear on
the display.
Tank heater
5.7
Set the internal tank heater
delay turn ON after heat pump
operation.
* Heater will turn ON only if
Backup heater "enabled" and
Tank heater "ON" condition.
Bivalent connection
5.8
To select to enable or disable
bivalent connection.
Yes
To select either auto control
pattern or SG ready input
control pattern.
* This selection only display
to select when optional pcb
connection set to Yes.
Default Setting
Setting Options / Display
No
Yes
Set T for Buffer
5 °C
Tank
Internal
1:30
No
Auto
27