Panasonic WH-ADF0309J3E5CM Service Manual page 114

Table of Contents

Advertisement

How to connect wiring to the terminal
For stranded wiring
(1) Cut the wire end with cutting pliers, then strip the
insulation to expose the stranded wiring about
10 mm and tightly twist the wire ends.
Stranded wire
(2) Using a Phillips head screwdriver, remove the
terminal screw(s) on the terminal board.
(3) Using a ring connector fastener or pliers, securely
clamp each stripped wire end with a ring pressure
terminal.
(4) Place the ring pressure terminal, and replace and
tighten the removed terminal screw using a
screwdriver.
Special
Screw
washer
Ring pressure
terminal
Terminal board
Wire
Ring
pressure
terminal
Screw and
Special washer
Ring
pressure
terminal
Wire
Examples of shield wires
(1) Remove cable coat not to scratch braided shield.
(2) Unbraid the braided shield carefully and twist the
unbraided shield wires tightly together. Insulate
the shield wires by covering them with an
insulation tube or wrapping insulating tape around
them.
(3) Remove coat of signal wire.
(4) Attach ring pressure terminals to the signal wires
and the shield wires insulated in Step (2).
114
Insulating tape Shield mesh
Insulating tape Shield mesh

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-71wf3eCu-2wz71ybe5

Table of Contents