ON:
Blinking:
OFF:
Wireless remote
controller
receiver display
Abnormal
display
H01
H02
Timer lamp
blinking
H03
H31
L04
L10
Operating
and standby
L13
lamps blinking
simultaneously
L18
P03
Operating
and standby
P04
lamp blinking
alternately
P05
P07
Timer and
standby
P13
lamp blinking
alternately
P14
Alarm contents
Primary (input) overcurrent detected
PAM trouble
Primary current CT sensor failure
HIC trouble
DC voltage not detected
Duplication of outdoor unit address
Outdoor unit capacity is not set or setting error
Indoor unit type setting error
Type of indoor/outdoor units is different
4-way valve locked trouble / operation failure
Compressor discharge temperature trouble
Condensing pressure trouble
Open phase detected
AC power supply trouble
HIC (IPM) temperature trouble
Valve error
Refrigerant circuit error
Wrong installation for refrigerant piping and
wiring
O
sensor detected
2
237
Error location
Check the refrigerant cycle (abnormal
overload operation)
Check the outdoor unit control PCB
Check the power supply
Check the outdoor unit control PCB
Compressor locked
Check the power supply
Check the outdoor unit control PCB
Check the outdoor unit control PCB
Check the HIC
Compressor locked
Valve blockage
Check the inter-unit control wiring
Replace the outdoor unit EEPROM
Capacity value re-setting
Replace the indoor unit EEPROM
Check the outdoor unit control PCB
Check the type of IU and OU, and re-set
address
Check the 4-way valve
Check the 4-way valve wiring
Check the outdoor unit control PCB
Check the refrigerant cycle (gas leak)
Trouble with the electronic expansion valve
Check the discharge temperature sensor
(TD)
Check the refrigerant cycle
Valve blockage
Heat exchanger obstruction
Check the power supply
Check the reactor wiring
Check the outdoor unit control PCB
Check the compressor wiring
Check the outdoor unit control PCB
Check the HIC
Compressor locked
Valve blockage
Valve blockage
Check the refrigerant circuit
Check the refrigerant piping and wiring
installation
Input from the O
sensor