Diagnosis
display
Abnormality
(Indoor
or
model:
protection
CS-XX /
control
S-XX /
WH-XX)
F93 / P29 /
Compressor
F14
abnormal
revolution
F94 / P04 /
Compressor
F12
discharge
pressure
overshoot
protection
F95 / P04 /
Outdoor cooling
F95
high pressure
protection
F96 / P07 /
Power transistor
F22
module
overheating
protection
F97 / P03 /
Compressor
F20
overheating
protection
F98 / H01 /
Total running
F16
current protection
F99 / P16 /
Outdoor direct
F23
current (DC) peak
detection
LED 1 illuminate is indicated that outdoor unit is operating normally. If the LED 1 is switched off or flashing, check the power supply and
self-diagnosis indication.
------ Illuminate
------ Flashing
Blank ------ OFF
LED
LED
LED
LED
LED
6
5
4
3
LED
Abnormality
Protection
2
1
judgement
operation
4 times
happen
within 20
minutes
4 times
happen
within 30
minutes
4 times
happen
within 20
minutes
4 times
happen
within 30
minutes
3 times
happen
within 30
minutes
3 times
happen
within 20
minutes
Continuous
happen for
7 times
246
Problem
-
Compressor
abnormal
revolution
-
Compressor
discharge
pressure
overshoot
-
Cooling high
pressure
protection
-
Power transistor
module overheat
-
Compressor
overheat
-
Total current
protection
-
Power transistor
module current
protection
Check location
 Power transistor
module faulty or
compressor lock
 Check
refrigeration
system
 Check
refrigeration
system
 Outdoor air
circuit
 PCB faulty
 Outdoor air
circuit (fan
motor)
 Insufficient
refrigerant
 Check
refrigeration
system
 Power source or
compressor lock
 Power transistor
module faulty or
compressor lock