Specifications - Panasonic WH-ADF0309J3E5CM Service Manual

Table of Contents

Advertisement

3. Specifications

Item
Performance Test Condition
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
Heating Capacity
Heating COP
Current
Input Power
Power Factor
Outdoor Ambient
Operation Range
Water Outlet
Internal Pressure Differential
Noise Level
Depth
Dimension
Width
Height
Net Weight
Liquid
Refrigerant Pipe Diameter
Gas
Room
Water Pipe Diameter
Shower
Water Drain Hose Inner Diameter
Motor Type
Pump
Input Power
Type
No. of Plates
Hot Water Coil
Size (W x H x L)
Water Flow Rate
Pressure Relief Valve Water Circuit
Type
Flow Switch
Measuring range
Pressure Release Valve
Unit
Condition
(Ambient/Water)
kW
BTU/h
W/W
A
kW
%
°C (min./max.)
°C (min./max.)
kPa
Condition
(Ambient/Water)
Presure Level
dB (A) H/L
Power Level dB H / L
mm
mm
mm
kg (lbs)
mm (inch)
mm (inch)
inch
mm (inch)
mm (inch)
W
mm
3
l/min (m
/h)
kPa
l/min
kPa
13
WH-ADC0309J3E5CM
EN 16147
EN 14825
1 / 21.6 / 4.9k
1 / 13.0 / 3.00k
A7W35
8.00
27300
4.21
9.0
1.90
92
-15 / 35 (Heating)
-15 / 46 (Heat recovery)
Heating (Tank): - / 65*,
Heating (Circuit): 20 / 55
22.3
A7W55
28 / -
41/ -
600
598
1880
108 (238)
6.35 (1/4)
12.70 (1/2)
1-1/4
3/4
12.00 (17/36)
DC Motor
173
Brazed Plate
38
71.4 x 333 x 121
Heating: 22.90 (1.4)
Open: 300, Close: 266 and below
VVX20 [Electronic pulse]
5 ~ 60
Open: 800, Close: 640 and below
A2W35
6.70
22800
3.25
9.9
2.06
90

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-71wf3eCu-2wz71ybe5

Table of Contents