Repair

Repair

Fluid Plate Assembly

This section describes how to remove and replace com-
ponents on the fluid plate assembly.
Prepare Fluid Plate Assembly for
Repair
1. Disconnect the CAN cable from the fluid plate.
2. Perform Pressure Relief Procedure on page 47.
3. Remove the fluid plate assembly shroud. See Fluid
Plate Assembly Parts, page 76.
103
124
129
125, 126, 127
F
. 44: Fluid Plate Assembly
IG
66
Repair Flow Meter
For complete flow meter (129) repair instructions refer to
the maintenance and repair section of manual 309834.
Remove Flow Meter from Mounting Plate
1. Prepare Fluid Plate Assembly for Repair, page
66.
2. Disconnect the flow meter cable (131) from the flow
meter sensor. See F
3. Disconnect the material hose.
4. Disconnect the swivel fitting (109) from the regula-
tor.
5. Loosen the four screws (127) and washers (125,
126); remove the bracket (124) and flow meter
(129).
6. The flow meter weighs approximately 15 lbs. (6.75
kg). Carefully lift it off the mounting plate (101).
131
109
. 44.
IG
101
108
r_pf0000_313377_18a
313377B