Errors; View Errors; Diagnose Errors; Clear Errors And Reset Control Unit - Graco PCF Instructions And Parts

Precision dispense system
Table of Contents

Advertisement

Errors

View Errors

When errors occur the highest priority active error is dis-
played in the menu bar. The previous 140 errors are dis-
played on the error report screens. See Run Mode,
page 90, for instructions on navigating to and through
the error report screens.
Error
Code

Error Codes and Troubleshooting

NOTE: Error codes are stored in the error log, and displayed on the error report screens. Gateway error num-
bers are reported over the Gateway interface (CGM or DGM).
Error
Gateway
Code
Error No.
Error Name
0000
0
No Active Errors
EP0X
1
Power Up
EC0X
2
Setup Values
Changed
313377B
There are three levels of errors: alarms, deviations, and
advisories. Alarms are critical and require immediate
correction; therefore, the system automatically shuts
down. Deviations are critical and require attention but
not immediately. Advisories are not critical but still
require attention.
NOTE:

Diagnose Errors

See Error Codes and Troubleshooting for valid error
codes, possible causes, and solutions.
Clear Errors and Reset Control
Unit
Press
unit.
Error
Description
Error Type
System Errors
No errors
n/a
Control box power up
Record only
Setup change notifica-
Record only
tion
Alarms set the dispenser ready signal LOW.
Advisories and deviations do not set the dispenser
ready signal LOW.
to clear an error before restarting the control
Cause
n/a
n/a
A setup value was
changed on the dis-
play
Errors
Solution
No action necessary
No action necessary
No action necessary if
changes were desired
55

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents