Graco PCF Instructions And Parts page 67

Precision dispense system
Table of Contents

Advertisement

Install Flow Meter on Mounting Plate
1. Rest the flow meter (129) and bracket (124) on the
fluid plate while threading the swivel fitting (109)
onto the regulator material inlet. See F
2. Tighten the swivel fitting to the regulator material
inlet.
3. Tighten the four screws (127) and washers (125,
126) to hold the bracket and flow meter in place.
126
127
129
F
. 45
IG
4. Check that the flow meter and regulator (108) are
still aligned.
5. Connect the material hose.
6. Connect the flow meter cable (131).
Replace Solenoid
1. Prepare Fluid Plate Assembly for Repair, page
66.
2. Disconnect FCM cable and all three air tubes.
3. Remove both screws (137) from valve bracket (118).
313377B
. 44.
IG
124
108
109
r_pf0000_313377_34a
125
4. Remove the dispense valve solenoid (132) and
replace it with a new solenoid.
137
118
132
F
. 46
IG
5. Secure the new solenoid to the bracket with screws.
6. Reconnect the FCM cable and all three air tubes.
Replace V/P Valve
1. Prepare Fluid Plate Assembly for Repair, page
66.
2. Disconnect the FCM cable and both air tubes.
3. Remove both valve screws (122) from valve bracket
(118).
4. Remove the V/P valve (121) and replace it with a
new V/P valve.
118
122
121
F
. 47
IG
Repair
r_pf0000_313377_33a
r_pf0000_313377_31a
67