Digital Input - Graco PCF Instructions And Parts

Precision dispense system
Table of Contents

Advertisement

Digital Input

The digital inputs function only when power is supplied to pin 51 and there is a ground connection to pin 70. See Pin
References, page 96, for details. The digital input is rated at 0-30 Vdc, and requires an NEC Class 2 power supply
connected to pin 51. The DGM provides optical isolation as shown in the following illustration.
Pins: 52 – 59, 71-78
Type: Sinking
Microcontroller
Microcontroller
313377B
Discrete Gateway
Discrete Gateway
Isolated Logic ICs
Isolated Logic ICs
Optical
Optical
Isolator
Isolator
Appendix B - DGM Connection Details
Maximum current draw: 3.6 mA
Customer Automation
Customer Automation
D-Sub Pin 51 (Isolated
D-Sub Pin 51 (Isolated
Logic Supply)
Logic Supply)
Digital Input
Digital Input
D-Sub Pin 70
D-Sub Pin 70
(Isolated Ground)
(Isolated Ground)
24VDC
24VDC