Configure Mode Settings

Set gun commands, including the dispense mode (pres-
sure, bead, shot, or full open) and flow rate or pressure
for each gun. The bead scale is also adjustable from the
Mode Settings screen.
NOTE: For a description of each dispense mode,
see Home Screen 1 - Fluid Plate, page 90.
1. With the system in setup mode, navigate to the Fluid
Plate set of screens.
2. Press
to scroll to the Mode Settings
screen (screen 2).
3. Press
to access the fields to make changes.
F
. 23
IG
4. Press
and
each gun that will be used to Pressure, Bead, Shot,
or Full Open. Press
5. Use the four arrow buttons to navigate to each Fixed
Command field. Enter the desired value for each
gun that will be used. Press
value.
30
to set the mode for
to enter each selection.
to enter each
NOTE: The ability to dispense from multiple guns
simultaneously is only allowed in either of the fol-
lowing scenarios.
Each gun is set to Pressure mode and has
identical Fixed Command values.
Each gun is set to Full Open mode.
Attempting to dispense from multiple guns simulta-
neously using any other combination will cause an
Incompatible Guns Settings alarm.
6. Press
to move to the Bead Scale field. Enter a
scale value between 50% and 150%. Press
enter the value.
7. Press
to exit edit mode.
to