Graco PCF Instructions And Parts page 26

Precision dispense system
Table of Contents

Advertisement

Installation
DeviceNet
NS
1
2
F
. 18: DeviceNet Fieldbus Connections
IG
Network Status (NS)
State
Off
Not online / No power
Green
On-line, one or more connections are
established
Flashing
On-line, no connections established
Green
(1 Hz)
Red
Critical link failure
Flashing
One or more connections timed-out
Red (1 Hz)
Alternating
Self test
Red/Green
Module Status (MS)
State
Off
No power or not initialized
Green
Initialized
Flashing
Missing or incomplete configuration, device
Green (1 Hz)
needs commissioning
Red
Unrecoverable Fault(s)
Flashing
Recoverable Fault(s)
Red (1 Hz)
Alternating
Self test
Red/Green
DeviceNet Connector (DC)
Pin
Signal
1
V-
Negative bus supply voltage
2
CAN_L
CAN low bus line
3
SHIELD
Cable shield
4
CAN_H
CAN high bus line
5
V+
Positive bus supply voltage
26
MS
3 4 5
TI11815A
DC
Description
Description
Description
PROFIBUS
OP
5
DC
F
. 19: PROFIBUS Fieldbus Connections
IG
Operation Mode (OP)
State
Off
Not online / No power
Green
On-line, data exchange
Flashing
On-line, clear
Green
Flashing Red
Parameterization error
(1 flash)
Flashing Red
PROFIBUS Configuration error
(2 flashes)
Status Mode (ST)
State
Off
No power or not initialized
Green
Initialized
Flashing
Initialized, diagnostic event(s) present
Green
Red
Exception error
PROFIBUS Connector (DC)
Pin
Signal
1
-
-
2
-
-
3
B Line
Positive RxD/TxD, RS485 level
4
RTS
Request to send
5
GND Bus
Ground (isolated)
6
+5V Bus
+5V termination power (isolated)
Output
7
-
-
8
A Line
Negative RxD/TxD, RS485 level
9
-
-
Housing Cable
Internally connected to the Anybus
Shield
protective earth via cable shield filters
according to the PROFIBS standard.
4
3
2
1
9 8 7 6
TI11816A
Description
Description
Description
313377B
ST