Repair
5. Secure the new V/P valve to the bracket with
screws.
6. Reconnect the FCM cable and both air tubes.
Replace Fluid Control Module
1. Prepare Fluid Plate Assembly for Repair, page
66.
2. Remove the four screws (128) from the valve
bracket (118), and remove the bracket. (Leave the
dispense valve solenoid (132) and V/P valve (121)
attached to the valve bracket.)
102
103
118
132
121
F
. 48
IG
3. Remove the following cables from FCM:
dispense valve solenoid cable
meter sensor cable
both V/P cables
I/O cable
inlet pressure transducer cable (ambient mod-
els only)
outlet pressure transducer cable
4. Remove the two screws from FCM (103) and
replace with a new FCM.
5. Secure the new FCM to the base (102) with screws.
6. Reconnect the cables listed in Step 3.
7. Reattach the valve bracket using screws.
68
128
r_pf0000_313377_30a
Replace Fluid Control Module Base
1. Prepare Fluid Plate Assembly for Repair, page
66.
2. Remove the FCM (103); follow Replace Fluid Con-
trol Module. (Leave the cables attached to the
FCM.)
3. Remove the power supply cable from the base
(102).
4. Remove the four screws (105) and ground screw
(106) from the base and replace it with a new base.
F
. 49
IG
5. Secure the base to the fluid plate (101) with screws.
6. Reconnect the power supply cable.
7. Reattach the FCM; follow Replace Fluid Control
Module.
102
105
106
103
313377B