Graco PCF Instructions And Parts page 57

Precision dispense system
Table of Contents

Advertisement

Error
Gateway
Code
Error No.
Error Name
B10X
32
Low Volume or
B20X
Low Mass
B1CX
33
Low Computed
B2CX
Target
B3CX
34
High Computed
B4CX
Target
CAD1
50
Fluid Plate Com-
munication Error
WND1
51
Fluid Plate Key
Token Error
P6D1
52
Outlet Pressure
Transducer Error
P6F1
53
Inlet Pressure
Transducer Error
313377B
Error
Description
Error Type
Control Center Errors (continued)
Material dispensed dur-
Alarm or
ing last dispense cycle
Deviation
below amount
(user select-
requested minus the
able)
allowed tolerance
Requested volume dif-
Alarm or
fers from entered pro-
Deviation
cess target by more
(user select-
than entered tolerance
able)
for style requested
Requested volume dif-
Alarm or
fers from entered pro-
Deviation
cess target by more
(user select-
than entered tolerance
able)
for style requested
Fluid Plate Errors
Communication lost
Alarm
between fluid plate and
ADM
Missing or invalid key
Alarm
token
Outlet pressure trans-
Alarm
ducer error
Inlet pressure trans-
Advisory
ducer error
Cause
Partially plugged tip or
Clean tip and/or supply
supply system
system
Insufficient flow to
Increase flow rate to
PCF regulator inlet
regulator inlet
PCF regulator is not
Incorrect style target
regulating correctly
volume or tolerance
setting
Check regulator;
repair if necessary
Entered process target
Enter correct process
incorrectly
target
Entered tolerance
Enter correct tolerance
incorrectly
Requested volume
Check automation pro-
incorrectly
gram
Automation problem
Verify automation is
correct
Entered process target
Enter correct process
incorrectly
target
Entered tolerance
Enter correct tolerance
incorrectly
Requested volume
Check automation pro-
incorrectly
gram
Automation problem
Verify automation is
correct
FCM is not
Reconnect or replace
communicating
CAN cable
FCM is not functioning Replace FCM if red
status LED is solid
FCM key token is
Verify FCM key token
required to run system
is installed
Verify FCM key token
is correct part number
Problem detected with
Verify outlet pressure
outlet pressure trans-
transducer is installed
ducer
and/or connected cor-
rectly
Replace if necessary
Problem detected with
Verify inlet pressure
inlet pressure trans-
transducer is installed
ducer
and/or connected cor-
rectly
Replace if necessary
Errors