Graco PCF Instructions And Parts page 59

Precision dispense system
Table of Contents

Advertisement

Error
Gateway
Code
Error No.
Error Name
WFD1
63
Flow Meter
Required
EJD1
64
Job Cycle Time
Out
WXD1
65
Fluid Plate Error
Detected
P3F1
66
Maximum Inlet
P4F1
Pressure
P3D1
67
Maximum Outlet
P4D1
Pressure
P1F1
68
Minimum Inlet
P2F1
Pressure
P1D1
69
Low Pressure
P2D1
313377B
Error
Description
Error Type
Fluid Plate Errors (continued)
Operating mode
Alarm or
requires flow meter.
Advisory
Advisory is issued if
(self-clearing)
fluid plate settings
require a flow meter but
meter is not present.
Alarm is issued if dis-
pense is attempted in
mode that requires a
flow meter but meter is
not present.
Job cycle time out
Alarm
Fluid plate error
Alarm
detected; includes any
error not covered by
another more specific
error
Inlet pressure to regula-
Alarm or
tor is above upper limit
Deviation
set for operation
(user select-
able)
Outlet pressure of regu-
Alarm or
lator is above upper
Deviation
limit set for operation
(user select-
able)
Inlet pressure to regula-
Alarm or
tor is below lower limit
Deviation
set for operation
(user select-
able)
Measured outlet pres-
Alarm or
sure less than desired
Deviation
outlet pressure minus
(user select-
tolerance
able)
Cause
Selected gun mode
Check gun mode set-
settings require flow
tings
meter
Purchase meter
enabled token for FCM
and install flow meter
FCM key token miss-
Check for FCM key
ing or invalid
token error
Automation signals did
Check automation pro-
not properly end job
gramming per job oper-
cycle
ating instruction
Incorrect set limit
Verify limit is set cor-
rectly
Material supply pres-
Decrease material
sure is too high
supply pressure
Failed transducer
Check transducer;
replace if necessary
Incorrect set limit
Verify limit is set cor-
rectly
Material supply pres-
Decrease material
sure is too high
supply pressure
Failed transducer
Check transducer;
replace if necessary
Incorrect set limit
Verify limit is set cor-
rectly
Material supply pres-
Increase crease mate-
sure is too low
rial supply pressure
Failed transducer
Check transducer;
replace if necessary
Incorrect limit set
Verify limit is set cor-
rectly
No or insufficient
Increase material flow
material flow
rate
Dispense valve nee-
Dislodge and inspect
dle is stuck closed
needle
Dispense valve leak-
Repair dispense valve
ing
Regulator not operat-
Repair regulator
ing correctly
Pump wink passed
Increase pump pres-
through outlet
sure
Failed transducer
Check transducer;
replace if failed
Errors
Solution
59

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents