Errors
Error
Gateway
Code
Error No.
Error Name
F6D1
54
Flow Meter Error Flow Meter error
WED1
55
V/P Error
WJD1
56
Dispense Valve 1
Error
WJD2
57
Dispense Valve 2
Error
WJD3
58
Dispense Valve 3
Error
WJD4
59
Dispense Valve 4
Error
WSD1
60
Incompatible Gun
Settings
F7D1
61
Closed Gun Flow System reading flow
V2D1
62
Low Analog
58
Error
Description
Error Type
Fluid Plate Errors (continued)
Alarm
V/P error
Alarm
Dispense valve 1 error
Alarm
Dispense valve 2 error
Alarm
Dispense valve 3 error
Alarm
Dispense valve 4 error
Alarm
Incompatible settings
Alarm
for multiple gun opera-
tion; attempted to dis-
pense
Alarm
meter pulses with
gun(s) closed
Analog command
Deviation
dropped below mini-
mum value (user
defined) while dispens-
ing
Cause
Problem detected with
Verify flow meter is
flow meter
installed and/or con-
nected correctly
Replace if necessary
Problem detected with
Verify outlet pressure
V/P
transducer is installed
and/or connected cor-
rectly
Replace if necessary
Problem detected with
Verify dispense valve 1
dispense valve 1
is installed and/or con-
nected correctly
Replace if necessary
Problem detected with
Verify dispense valve 2
dispense valve 2
is installed and/or con-
nected correctly
Replace if necessary
Problem detected with
Verify dispense valve 3
dispense valve 3
is installed and/or con-
nected correctly
Replace if necessary
Problem detected with
Verify dispense valve 4
dispense valve 4
is installed and/or con-
nected correctly
Replace if necessary
Attempted to dis-
Check gun mode set-
pense from multiple
tings (on fluid plate
guns with incompatible
setup screen)
settings
Verify automation pro-
gramming
Dispense hose leak
Check hose; replace if
needed
Flow meter providing
Replace flow meter
false pulses
sensor or calibrate
meter
Dispense valve not
Repair dispense valve
operating correctly
Bad or loose com-
Check command cable
mand cable connec-
and connection
tion
Entered command
Enter correct com-
mode incorrectly
mand code
Automation program
Verify correct automa-
error
tion program
Solution
313377B