Graco PCF Instructions And Parts page 58

Precision dispense system
Table of Contents

Advertisement

Errors
Error
Gateway
Code
Error No.
Error Name
F6D1
54
Flow Meter Error Flow Meter error
WED1
55
V/P Error
WJD1
56
Dispense Valve 1
Error
WJD2
57
Dispense Valve 2
Error
WJD3
58
Dispense Valve 3
Error
WJD4
59
Dispense Valve 4
Error
WSD1
60
Incompatible Gun
Settings
F7D1
61
Closed Gun Flow System reading flow
V2D1
62
Low Analog
58
Error
Description
Error Type
Fluid Plate Errors (continued)
Alarm
V/P error
Alarm
Dispense valve 1 error
Alarm
Dispense valve 2 error
Alarm
Dispense valve 3 error
Alarm
Dispense valve 4 error
Alarm
Incompatible settings
Alarm
for multiple gun opera-
tion; attempted to dis-
pense
Alarm
meter pulses with
gun(s) closed
Analog command
Deviation
dropped below mini-
mum value (user
defined) while dispens-
ing
Cause
Problem detected with
Verify flow meter is
flow meter
installed and/or con-
nected correctly
Replace if necessary
Problem detected with
Verify outlet pressure
V/P
transducer is installed
and/or connected cor-
rectly
Replace if necessary
Problem detected with
Verify dispense valve 1
dispense valve 1
is installed and/or con-
nected correctly
Replace if necessary
Problem detected with
Verify dispense valve 2
dispense valve 2
is installed and/or con-
nected correctly
Replace if necessary
Problem detected with
Verify dispense valve 3
dispense valve 3
is installed and/or con-
nected correctly
Replace if necessary
Problem detected with
Verify dispense valve 4
dispense valve 4
is installed and/or con-
nected correctly
Replace if necessary
Attempted to dis-
Check gun mode set-
pense from multiple
tings (on fluid plate
guns with incompatible
setup screen)
settings
Verify automation pro-
gramming
Dispense hose leak
Check hose; replace if
needed
Flow meter providing
Replace flow meter
false pulses
sensor or calibrate
meter
Dispense valve not
Repair dispense valve
operating correctly
Bad or loose com-
Check command cable
mand cable connec-
and connection
tion
Entered command
Enter correct com-
mode incorrectly
mand code
Automation program
Verify correct automa-
error
tion program
Solution
313377B

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents