Graco PCF Instructions And Parts page 56

Precision dispense system
Table of Contents

Advertisement

Errors
Error
Gateway
Code
Error No.
Error Name
EAU0
3
Download to
USB in Process
EBU0
4
Download to
USB Complete
WSU0
5
USB configura-
tion error
WNC0
10
ADM Key Token
Error
WMC0 19
Display Error
Detected
CAC0
20
CGM Communi-
cation Error
WMG0 21
Gateway Map
Error
CBG0
22
Gateway Reset
WMG0 29
Gateway Error
Detected
B7C0
30
Style Out of
Range
B40X
31
High Volume or
B30X
High Mass
56
Error
Description
Error Type
Control Center Errors
Information is currently
Advisory
being downloaded to
(self-clearing)
USB
Download to the USB is
Advisory
complete
(self-clearing)
USB configuration error Advisory
Missing or invalid key
Alarm
token
ADM error detected;
Alarm
includes any error not
covered by another
more specific error
Communication lost
Advisory
between CGM and
ADM
Missing or invalid map
Advisory
Gateway reset
Advisory
(self-clearing)
Gateway error
Alarm
detected; includes any
error not covered by
another more specific
error
Style is out of range
Alarm
Material dispensed dur-
Alarm or
ing last dispense cycle
Deviation
was above amount
(user select-
requested plus the
able)
allowed tolerance
Cause
n/a
No action necessary
n/a
No action necessary
USB configuration
Reinstall system soft-
invalid or not present
ware on display
An ADM key token is
Verify the key token is
required to run the
installed
system
Verify the key token
part number is correct
for the PCF ADM
ADM and CGM are no
Reconnect or replace
longer communicating
CAN cable
CGM is not functioning Replace the CGM if the
red status LED is solid
Missing or invalid
Install PCF map in
Gateway map
Gateway
Gateway setting(s)
Wait for reset to com-
changed
plete before attempt-
ing automation control
Style requested by
Use a style number
automation controller
that is in range
exceeds number of
Increase number of
styles in system
styles in PCF; pur-
chase accessory key
token
PCF regulator is not
Check regulator and
regulating correctly
repair if necessary
Incorrect style target
Enter correct values or
volume or tolerance
set tolerance to 0% to
disable fault
Solution
313377B

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents