System Setup
Setup Maintenance
Schedule/Parameters
Set the volume (or hours) limit that will trigger a mainte-
nance advisory for the fluid supply, V/P regulator, fluid
regulator, flow meter, and all four guns.
NOTE: Hours is shown instead of Volume for fluid
plates without a flow meter.
The Volume (or Hours) column displays the current
totalizer value. If this value exceeds the set limit, the
value will turn red and a maintenance advisory is
issued. See Maintenance Screen, page 92, for more
information about maintenance totalizers.
To set limits:
1. With the system in setup mode, navigate to the Fluid
Plate set of screens.
2. Press
to scroll to the Maintenance
Advisory Limits screen (screen 7).
3. Press
to access the fields to make changes.
F
. 28
IG
4. Enter the desired limit for the air supply and press
to enter the selection.
5. Press
to move to the next field. Repeat Step 4
for each field.
34
6. Press
to exit edit mode.
To reset a totalizer value:
1. Follow Steps 1-3 of To set limits: to make changes
in the Maintenance Advisory Limits screen.
2. Press
to scroll to the system compo-
nent to reset.
3. Press
to reset the value.

Configure Gateway Settings

Gateway settings differ for each system. See Gateway
Setup Screens, page 84, for guidelines on configuring
each type of Gateway interface.

Setup Styles

The PCF system can store up to 255 styles. See Styles,
page 41, for more information about styles and instruc-
tions on setting up styles.

Configure Advanced Settings

Use the advanced settings to set or change the format
and display units, such as the language, date format,
and pressure units, for all PCF screens. See Setup
Mode, page 83, for advanced setting guidelines.