Errors
Error
Gateway
Code
Error No.
Error Name
P3D1
70
High Pressure
P4D1
F1D1
71
Low Flow Rate
F2D1
F3D1
72
High Flow Rate
F4D1
60
Error
Description
Error Type
Fluid Plate Errors (continued)
Measured outlet pres-
Alarm or
sure greater than
Deviation
desired outlet pressure
(user select-
plus tolerance
able)
Measured flow rate less
Alarm or
than desired flow rate
Deviation
minus tolerance
(user select-
able)
Measured flow rate
Alarm or
greater than desired
Deviation
flow rate plus tolerance
(user select-
able)
Cause
Incorrect limit set
Verify limit is set cor-
rectly
Dispense hose/device
Clean/replace
plugged
hose/device
Failed transducer
Check transducer;
replace if failed
Regulator is not clos-
Repair regulator
ing completely when it
should
Fluid supply too low to
Increase fluid supply
achieve desired flow
pressure or check for
rate
clogged filter
Tip plugged
Clean/replace tip
No air pressure to
Turn on air to solenoid
solenoid valves
valves
No flow meter signal
Check cable and sen-
sor
No material supply
Replace drum or turn
on pumps
Incorrect flow toler-
Enter correct toler-
ance of flow fault time
ance or flow fault time
Operating below mini-
Increase fluid pres-
mum regulator operat-
sure above regulator
ing pressure
minimum
Regulator worn or not
Repair regulator
operating correctly
Flow meter providing
Replace flow meter
false pulses
sensor
Incorrect flow fault tol-
Enter correct toler-
erance or flow fault
ance or flow fault time
time
Solution
313377B

Advertisement

Table of Contents

Troubleshooting