STEP
FAULT CODE/SYMPTOM
1
8/6 MOMENT PIN SENSOR FAULT The moment pin has
reported a fault flag
Table 6-14. Load Moment Pin Troubleshooting: New Moment Pin Detected Fault
STEP
FAULT CODE/SYMPTOM
1
8/6 NEW MOMENT PIN DETECTED FAULT A moment pin was
detected on the system different from the one used to cali-
brate the machine.
3121142
Table 6-13. Load Moment Pin Troubleshooting: Moment Pin Sensor Fault
Use the Analyzer, scroll to the DIAGNOS-
TICS menu, press ENTER, then scroll to
the MOMENT menu, and press ENTER,
check to see if PIN E FLAGS has any num-
bers on the screen display.
Perform the Boom Sensor calibration
process to accept the new load moment
pin.
REPAIR
Replace load moment pin &
Perform the Boom Sensor cali-
bration process
REPAIR
Verify BCS check and review all
faults prior to contacting JLG
Service Dept.
– JLG Lift –
SECTION 6 - JLG CONTROL SYSTEM
YES
Contact JLG Service Dept.
YES
Contact JLG Service Dept.
NO
NO
6-131