JLG 1200SJP Service Maintenance Manual page 419

Hide thumbs Also See for 1200SJP:
Table of Contents

Advertisement

Diagnostics Submenu
Parameter (Displayed on
(Displayed on Analyzer
Analyzer 2
st
1
Line)
ENVELOPE:
LENGTH
ANGLE 1
ANGLE 2
A/D LNGTH
A/D ANG1
A/D ANG2
CAN STATISTICS:
RX/SEC
TX/SEC
BUS OFF
PASSIVE
3121142
Table 6-5. Machine Diagnostics Parameters
Parameter Value
nd
Line)
(Displayed on Analyzer 2
XXXX.X
XX.X
XX.X
XXXXX
XXXXX
XXXXX
XXX
XXX
XX
XX
– JLG Lift –
SECTION 6 - JLG CONTROL SYSTEM
nd
Line)
Displayed if MODEL NUMBER = 7 or 8
Displays the current indicated boom length in inches.
Displays the current indicated boom angle 1 in degrees.
Displays the current indicated boom angle 2 in degrees.
Displays the current indicated boom length in A/D counts.
Displays the current indicated boom angle 1 in A/D counts or raw angle if cali-
brated.
Displays the current indicated boom angle 2 in A/D counts or raw angel if cali-
brated.
CAN Statistics as detected by the Ground Module
Displays the number of received messages per second
Displays the number of transmitted messages per second
Displays the number of bus off occurrences
Displays the number of bus passive occurrences
Description