7. Hydraulic Oil
Lube Point(s) - Fill Cap
Capacity - 55 gallons (208 liters) Tank
Lube - HO
Interval - Check level daily. Change every 2 years or 1200
hours of operation.
8. Suction Strainers (In Tank)
Lube Point(s) - 2
Interval - Every 2 years or 1200 hours of operation.
Remove and clean at time of hydraulic oil
3121142
FULL LEVEL (HOT OIL)
FULL LEVEL (COLD OIL)
change.
– JLG Lift –
SECTION 1 - SPECIFICATIONS
9. Oil Change w/Filter - Deutz
Lube Point(s) - Fill Cap/Spin-on Element
Capacity -
5 Quarts (4.5 L) Cooling System
11 Quarts (10.5 L) w/Filter
16 Quarts (15 L) Total Capacity
Lube - EO
Interval - Check level daily; change every 500 hours or
six months, whichever comes first. Adjust final oil
level by mark on dipstick. Refer to Figure 1-2., Deutz
Engine Dipstick.
MINIMUM OIL
LEVEL
MAXIMUM OIL
LEVEL
MINIMUM LEVEL,
OIL HOT
MINIMUM LEVEL,
OIL COLD
MAXIMUM LEVEL,
OIL COLD
NOTE: Hot oil checks should not be made until the engine
has been shut down for a period of 5 minutes.
Figure 1-2. Deutz Engine Dipstick
MAXIMUM LEVEL,
OIL HOT
1-9