JLG 1200SJP Service Maintenance Manual page 442

Hide thumbs Also See for 1200SJP:
Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
3. Plug the analyzer into the connector inside the Ground
control box.
4. Pull out the Emergency Stop switch and start the
engine.
5. The analyzer screen should read:
6. Use the arrow button to reach ACCESS LEVEL 2. Hit Enter.
7. Enter the Access Code, 33271.
8. Use the right Arrow key to reach CALIBRATIONS. Hit
Enter.
6-66
9. Use the arrow keys to reach the TILT SENSOR. The screen
should read:
10. Press ENTER.
11. When prompted, swing turntable 180° to opposite end
of chassis.
12. Press ENTER. The screen should read:
13. Upon completing swing calibration, swing turntable
180° back to the stowed position.
14. Hit ESC twice to go back to CALIBRATIONS.