JLG 1200SJP Service Maintenance Manual page 498

Hide thumbs Also See for 1200SJP:
Table of Contents

Advertisement

SECTION 6 - JLG CONTROL SYSTEM
7. If the CANbus link from the Boom Length & Angle Mod-
ule is lost, you will see the Platform Module SW version,
Platform Module HW Rev, Platform Module SN, Ground
Module SW version, Ground Module HW Revision,
Ground Module SN, Chassis SW version, but you will not
see the Boom Length & Angle Module SW revision. The
Analyzer screen will read:
6-122
TROUBLESHOOTING: BLAM CAN COMMUNICATIONS LOST
NOTE: BLAM CAN COMMUNICATIONS LOST (6/6) (Help Fault Code
6-6) basically means all communication linked from the
Ground Module to the Boom Length &: Angle Module is
lost. This also includes the lift cylinder load moment pin as
well.
– JLG Lift –
3121142

Advertisement

Table of Contents
loading

This manual is also suitable for:

1350sjp

Table of Contents