SECTION 6 - JLG CONTROL SYSTEM
Flash
DTC
Sequence
Code
454
45
4
455
45
5
456
45
6
457
45
7
458
45
8
459
45
9
4510
45
10
4511
45
11
4512
45
12
4513
45
13
4514
45
14
4515
45
15
4516
45
16
4517
45
17
4518
45
18
4519
45
19
4520
45
20
4521
45
21
4522
45
22
4523
45
23
6-94
Table 6-6. Diagnostic Trouble Code Chart
Fault Message
MAIN LIFT PVG VALVE - HIGH VOLTAGE
TOWER LIFT PVG VALVE - HIGH VOLTAGE
TOWER TELESCOPE PVG VALVE - HIGH VOLTAGE
MAIN LIFT PVG VALVE - LOW VOLTAGE
TOWER LIFT PVG VALVE - LOW VOLTAGE
TOWER TELESCOPE PVG VALVE - LOW VOLTAGE
MAIN LIFT PVG VALVE - STUCK NEUTRAL
TOWER LIFT PVG VALVE - STUCK NEUTRAL
TOWER TELESCOPE PVG VALVE - STUCK NEUTRAL
MAIN LIFT PVG VALVE - STUCK EXTENDED
TOWER LIFT PVG VALVE - STUCK EXTENDED
TOWER TELESCOPE PVG VALVE - STUCK EXTENDED
MAIN LIFT PVG VALVE - STUCK RETRACTED
TOWER LIFT PVG VALVE - STUCK RETRACTED
TOWER TELESCOPE PVG VALVE - STUCK RETRACTED
MAIN LIFT PVG VALVE - OBSTRUCTED
TOWER LIFT PVG VALVE - OBSTRUCTED
TOWER TELESCOPE PVG VALVE - OBSTRUCTED
MAIN LIFT PVG VALVE - COMMAND IMPROPER
TOWER LIFT PVG VALVE - COMMAND IMPROPER
Fault Description
The Main Lift PVG Valve supply
voltage is high.
The Tower Lift PVG Valve supply
voltage is high.
The Tower Telescope PVG Valve
supply voltage is high.
The Main Lift PVG Valve supply
voltage is low.
The Tower Lift PVG Valve supply
voltage is low.
The Tower Telescope PVG Valve
supply voltage is low.
The Main Lift PVG Valve is stuck
in its neutral position.
The Tower Lift PVG Valve is stuck
in its neutral position.
The Tower Telescope PVG Valve
is stuck in its neutral position.
The Main Lift PVG Valve is stuck
in its extended position.
The Tower Lift PVG Valve is stuck
in its extended position.
The Tower Telescope PVG Valve
is stuck in its extended position.
The Main Lift PVG Valve is stuck
in its retracted position.
The Tower Lift PVG Valve is stuck
in its retracted position.
The Tower Telescope PVG Valve
is stuck in its retracted position.
The Main Lift PVG Valve is
obstructed
The Tower Lift PVG Valve is
obstructed
The Tower Telescope PVG Valve
is obstructed
The Main Lift PVG Valve com-
mand is improper.
The Tower Lift PVG Valve com-
mand is improper.
– JLG Lift –
Check
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
3121142

Advertisement

Table of Contents
loading

This manual is also suitable for:

1350sjp

Table of Contents