Flash
DTC
Sequence
Code
9941
99
41
9942
99
42
9943
99
43
9944
99
44
9945
99
45
9975
99
75
9979
99
79
3121142
Table 6-6. Diagnostic Trouble Code Chart
Fault Message
CHASSIS SENSOR SUPPLY OUT OF RANGE LOW
BLAM BACKUP COMMUNICATIONS LINK FAULTY
BLAM BACKUP COMMUNICATIONS LOST - HYDRAULICS SUSPENDED
CURRENT FEEDBACK GAINS OUT OF RANGE
CURRENT FEEDBACK CALIBRATION CHECKSUM INCORRECT
LOAD PIN NOT CALIBRATED
FUNCTIONS LOCKED OUT - GROUND MODULE SOFTWARE VERSION
IMPROPER
Fault Description
The Chassis Sensors supply volt-
age is low.
The BLAM backup communica-
tions link test was activated at
startup, but no communication
connection established/main-
tained.
The BLAM backup communica-
tions link was activated, but no
communication connection
established/maintained.
The factory set current feedback
gains are out of range.
The factory set current feedback
checksum is not correct.
The Load Pin has not been cali-
brated.
Temporary fault for the telemat-
ics project. The model needs to
be a 600S or 1350S if not this
fault will be generated and Plat-
form controls will be prevented.
This fault was to insure that the
software will only work for
these two models.
– JLG Lift –
SECTION 6 - JLG CONTROL SYSTEM
Check
- BLAM equipped vehicles only.
-1250
- BLAM equipped vehicles only.
-1250
-1250
6-107