JLG 1200SJP Service Maintenance Manual page 471

Hide thumbs Also See for 1200SJP:
Table of Contents

Advertisement

Flash
DTC
Sequence
Code
4524
45
24
4525
45
25
4526
45
26
4527
45
27
4528
45
28
4529
45
29
4530
45
30
4531
45
31
4532
45
32
4533
45
33
4534
45
34
4535
45
35
4536
45
36
4537
45
37
4538
45
38
4539
45
39
4540
45
40
4541
45
41
4542
45
42
4543
45
43
4544
45
44
4545
45
45
3121142
Table 6-6. Diagnostic Trouble Code Chart
Fault Message
TOWER TELESCOPE PVG VALVE - COMMAND IMPROPER
MAIN LIFT PVG VALVE - TIMEOUT
TOWER LIFT PVG VALVE - TIMEOUT
TOWER TELESCOPE PVG VALVE - TIMEOUT
MAIN LIFT PVG VALVE - SETUP FAULT
TOWER LIFT PVG VALVE - SETUP FAULT
TOWER TELESCOPE PVG VALVE - SETUP FAULT
MAIN LIFT PVG VALVE - SENT UNRECOGNIZED FAULT
TOWER LIFT PVG VALVE - SENT UNRECOGNIZED FAULT
TOWER TELESCOPE PVG VALVE - SENT UNRECOGNIZED FAULT
MAIN LIFT PVG VALVE - PARAMETERS INCORRECT
TOWER LIFT PVG VALVE - PARAMETERS INCORRECT
TOWER TELESCOPE PVG VALVE - PARAMETERS INCORRECT
MAIN LIFT PVG VALVE - LOCATION IMPROPER
TOWER LIFT PVG VALVE - LOCATION IMPROPER
TOWER TELESCOPE PVG VALVE - LOCATION IMPROPER
MAIN LIFT PVG VALVE - WIRING INCORRECT
TOWER LIFT PVG VALVE - WIRING INCORRECT
TOWER TELESCOPE PVG VALVE - WIRING INCORRECT
MAIN LIFT PVG VALVE - SPOOL CANNOT REACH NEUTRAL
TOWER LIFT PVG VALVE - SPOOL CANNOT REACH NEUTRAL
TOWER TELESCOPE PVG VALVE - SPOOL CANNOT REACH NEUTRAL
Fault Description
The Tower Telescope PVG Valve
command is improper.
The Main Lift PVG Valve has
timed out.
The Tower Lift PVG Valve has
timed out.
The Tower Telescope PVG Valve
has timed out.
The Main Lift PVG Valve has a
setup fault.
The Tower Lift PVG Valve has a
setup fault.
The Tower Telescope PVG Valve
has a setup fault.
The Main Lift PVG Valve has an
unrecognized fault.
The Tower Lift PVG Valve has an
unrecognized fault.
The Tower Telescope PVG Valve
has an unrecognized fault.
The Main Lift PVG Valve parame-
ters are incorrect.
The Tower Lift PVG Valve param-
eters are incorrect.
The Tower Telescope PVG Valve
parameters are incorrect.
The Main Lift PVG Valve is in the
wrong location.
The Tower Lift PVG Valve is in the
wrong location.
The Tower Telescope PVG Valve
is in the wrong location.
The Main Lift PVG Valve has
incorrect wiring.
The Tower Lift PVG Valve has
incorrect wiring.
The Tower Telescope PVG Valve
has incorrect wiring.
X
X
X
– JLG Lift –
SECTION 6 - JLG CONTROL SYSTEM
Check
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.