Table 6-6. Diagnostic Trouble Code Chart
Fault Message
PLATFORM CONTROL VALVE - SHORT TO BATTERY
MAIN LIFT APU VALVE - SHORT TO GROUND
MAIN LIFT APU VALVE - OPEN CIRCUIT
MAIN LIFT APU VALVE - SHORT TO BATTERY
MAIN LIFT PILOT - PRESSURE FAILURE
MAIN LIFT PILOT - NO PRESSURE
MAIN LIFT PILOT - PRESSURE SWITCH FAILURE
TOWER LIFT APU VALVE - STUCK OPEN
TOWER LIFT ENABLE VALVE - STUCK OPEN
TOWER LIFT ENABLE VALVE - SHORT TO GROUND
TOWER LIFT ENABLE VALVE - OPEN CIRCUIT
TOWER LIFT ENABLE VALVE - SHORT TO BATTERY
TOWER TELESCOPE APU VALVE - SHORT TO GROUND
TOWER TELESCOPE APU VALVE - OPEN CIRCUIT
TOWER TELESCOPE APU VALVE - SHORT TO BATTERY
LIFT PILOT VALVE - SHORT TO GROUND
LIFT PILOT VALVE - OPEN CIRCUIT
LIFT PILOT VALVE - SHORT TO BATTERY
LIFT DOWN AUX VALVE - SHORT TO GROUND
Fault Description
There is a Short to Battery to the
Platform Control Valve.
There is a Short to Ground to the
Main Lift APU Valve.
There is an Open Circuit to the
Main Lift APU Valve.
There is a Short to Battery to the
Main Lift APU Valve.
The Main Lift Pilot has a Pressure
Failure.
The Main Lift Pilot has No Pres-
sure.
The Main Lift Pilot has a Pressure
Switch Failure.
The Tower Lift APU Valve is Stuck
Open
The Tower Lift Enable Valve is
Stuck Open
There is a Short to Ground to the
Tower Lift Enable Valve.
There is an Open Circuit to the
Tower Lift Enable Valve.
There is a Short to Battery to the
Tower Lift Enable Valve.
There is a Short to Ground to the
Tower Telescope APU Valve.
There is an Open Circuit to the
Tower Telescope APU Valve.
There is a Short to Battery to the
Tower Telescope APU Valve.
There is a Short to Ground to the
Lift Pilot Valve.
There is an Open Circuit to the
Lift Pilot Valve.
There is a Short to Battery to the
Lift Pilot Valve.
There is a Short to Ground to the
Lift Down Auxiliary Valve.
– JLG Lift –
SECTION 6 - JLG CONTROL SYSTEM
Check
- Electronic leveling system
equipped vehicles only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- 1250AJP only.
- Gravity Lift Down equipped vehi-
cles only.
- Gravity Lift Down equipped vehi-
cles only.
- Gravity Lift Down equipped vehi-
cles only.
- Gravity Lift Down equipped vehi-
cles only.
6-89

Advertisement

Table of Contents
loading

This manual is also suitable for:

1350sjp

Table of Contents